124 Display Parameter Setting Introduction

See the PDF file here

1) After entering the power-on state, press and hold the function key for 1-3S and adjustment key

to enter into the setting mode( ). At this time, the speed position will display PXX, XX indicates the

several parameters( ), and the mileage position will display the specific numbers of different

parameters.

2)Short press the power button in the setting mode to switch between different parameters

Explanation of each parameter:

1.//Backlight brightness factory default: 8

Speed position display ‘P01’ Mileage position display range ‘0-8’

3.//Voltage mode factory default: 36V

Speed position display ‘P03’ Mileage position display range ‘24, 36,48 ’Unit: V

4.//Sleep time factory default: 10 minutes

Speed position display ‘P04’ Mileage position display range ‘0-255’ Unit: minute

When set to 0, it means that hibernation is turned off (that is, no hibernation).8.//Wheel diameter setting (wheel diameter) Factory default value: 20.0 inches

Speed position display ‘P08’ Mileage position display range ‘1.0-50.0’ Unit: inch

9.//Speed measurement magnetic steel number setting (the number of Hall pulses to be detected when the wheel

rotates for 1 week) Factory default value: 30

Speed position display ‘P09’ Mileage position display range ‘0-255’

10.//Speed limit value setting factory default: 25

Speed position display ‘P10’ Mileage position display range ‘0-255’ Unit: km / h

When it is 0, it means that the speed limit is cancelled

11.//Startup mode setting factory default value: 0 when it means zero start and 1 when it means non-zero start

Speed position display ‘P11’ Mileage position display range ‘0,1’

0: Zero start

1: non-zero start

26 // ODO total mileage reset setting

Speed position display ‘P26’ Mile position display ‘Current total mileage value’

Note: When long press the function key or the adjustment key, the current total mileage is cleared.

(3)Short press the adjustment key to add the parameter value. If 7 parameters are now entered, short press the

adjustment key to add the parameter value.(4) Short press the function key to decrease the parameter value. If 7 parameters are entered now, short press the

function key to decrease the parameter value.

(5)Press and hold the function key and the adjustment key to exit the setting.

In the normal operation interface, short press the adjustment key. The mileage position display can be switched back

and forth between these display interfaces.

ODO (Total mileage)—-TRIP (Single mileage)—–Power supply voltage value—–Fault code

Under the fault code display, the current fault code will flash.

Fault code description:

‘EE-1’ means that the current meter cannot receive the controller data or the received data is error data.

‘EE-2’ means that the controller cannot receive the meter data or the received data is error data.

‘EE-3’ indicates that the current controller is malfunctioning.

‘EE-4’ indicates that the current motor Hall is faulty.

‘EE-5’ indicates that the current motor is out of phase.

‘EE-6’ indicates that the current handlebar malfunctions.

‘EE-7’ indicates a malfunction of the current brake lever.

‘EE-8’ indicates that the current boost sensor is malfunctioning.

‘EE-9’ indicates that the current motor is under voltage p